Home/Services/Arc Flash Studies

Arc Flash Studies & Electrical Safety

Arc flash studies, labelling, protection coordination and short circuit analysis for mining, utility and industrial sites in Perth and across WA.

Know the hazard at every board

Electrical Systems Engineering carries out arc flash studies, labelling, protection coordination and short circuit analysis for mining, utility and industrial sites in Perth and across WA. Because we also design and build switchboards and MCCs, we can fix what a study finds, from protection settings to arc flash detection fitted in our Landsdale workshop.

Electrical Safety

What We Do

Arc flash studies

We calculate the arc flash hazard at each switchboard and MCC on your site, so you know the hazard at every board before anyone opens or operates it.

Arc flash labelling

Each board gets labels that show the hazard at that point, so workers can choose the right controls before they open it.

Protection coordination

We review and coordinate protection settings so the nearest device clears a fault, balancing selectivity against arc flash energy.

Short circuit analysis

Fault level calculations that confirm your switchgear can safely withstand and interrupt the fault currents on your network.

Arc flash detection systems

Arc flash detection relays, such as ABB TVOC, that trip the upstream breaker as soon as an arc is detected.

Project

1600A Main Switchboard

Temporary 1600Amp switchboard featuring ABB TVOC arc flash detection and 6x 630A outgoing circuits.

  • Full concept & detailed design
  • 1600A incomer
See the Subiaco 1600A switchboard project

Frequently Asked Questions

What is an arc flash study?

An engineering assessment of the electrical network that calculates how much energy an arc fault would release at each switchboard. The results set the labels, protective equipment and work procedures for each board.

Can you reduce the arc flash hazard on an existing board?

Often, yes. Changes to protection settings can shorten the time an arc lasts, which lowers the energy released. We assess each board and recommend what is practical.

Do you build arc flash protection into new switchboards?

Yes. Our switchboards and MCCs are designed with arc flash protection, and we fit detection systems where needed, such as ABB TVOC arc flash detection on a 1600A main switchboard for a Subiaco wastewater plant.

Where do you work?

We are based in Landsdale, Perth, and work on mining, utility and industrial sites across Western Australia, including the Pilbara.

Need an Arc Flash Study?

Send us your single-line diagram and a list of boards, and we'll scope the study and quote it.